| 首页 > 最新国际求购Trade买家Key > 最新国际求购Trade买家Key | |||
| Buy Three Phase Transformer 求购采购信息 Buying leads | |||
| 发布时间: 2024-6-28 浏览:8 | |||
|
发 布 人:todaytex 发布人:QQ 1407106692 ; 微信:1407106692 联系网址:http://www.todaytex.com |
|||
|
公司:Buy Three Phase Transformer 求购采购信息 Buying leads 国家:follow 联系人:follow 地址: 采购内容Buy Three Phase Transformer [hide]详细内容[/hide]1. Requested Quantity1 Transformers QTY with Surge arrestors 1.1 Single phase transformer 15/0.24kv - 15KVA 161.2 Single phase transformer 15/0.24kv - 25KVA 101.3 Three phase transformer 15/0.4kv - 25KVA 571.4 Three phase transformer 15/0.4kv - 50KVA 51.5 Three phase transformer 15/0.4kv - 100KVA 31.6 Single phase transformer 30/0.24kv - 15KVA 161.7 Single phase transformer 30/0.24kv - 25KVA 101.8 Three phase transformer 30/0.4kv - 25KVA 571.9 Three phase transformer 30/0.4kv - 50KVA 51.1 Three phase transformer 30/0.4kv - 100KVA 31822. Technical Specifications1. TRANSFORMERS1.1. General technical conditionsI. STANDARDSThe equipments shall comply with this specification and the following standards:- IEC 60076 : power transformer, Or- ANSI/IEEE C 57.12.90: Test code for liquid immersed distribution power and regulating transformer- ANSI/IEEE C 57.12.80: Power and Distribution transformer- ANSI/IEEE C 57.12.00: Liquid-immersed distribution Power and regulating transformer,II. ENVIRONMENTAL CONDITIONS- Average ambient temperature for year: 25- Minimum ambient temperature: +10- Altitude: 2000 m- Pollution level: I (according to IEC 60815)Bushing- Bushings could be porcelain or silicone rubber type. If silicone type proposed, 5000-hour aging tests referring to IEC 61109 shall be attached to the technical proposal- All bushings shall be waterproof.- The nominal creepage distance of bushings shall not be less than 280 mm. - HV Terminals shall be designed to receive all sizes of conductors from 34.4 mm up to 54.6 mm, for Aluminium Alloy (AAAC) and Aluminium (in ACSR conductor type) - LV bushings should be equipped with lugs accepting copper and Aluminum conductor - The diameter of the threaded rod of HTA bushings should be equal to 12 mmAccessoriesa) Fixation: The transformer is designed for pole mounting; the mounting system of the transformer must be adaptable to structure.b) Lifting hooks The lifting hooks shall be placed so that when lifting the transformer, lifting sling remains far from the bushing.c) PaintingProtection against corrosion of the tank and other metal accessories shall be ensured by a protective coating on the basis of ISO 12944.d) Nameplate Every transformer must be equipped with a name plate with all information us specified in referring standard.e) Tap changer The transformers shall be equipped with an externally operated off-load tap changer on the high voltage winding. The tapping range shall be in three position minimum -5%, 0, +5%f) Surge arrestorsEvery transformers shall be supplied with MV no gap surge arrestors per transformer phase.The surge arrestors shall be supplied with mounting brackets and connection leads.Country:France系联系方式Co:performance 21Add:7 rue Voltaire, TARBES, FranceTel:33-466-3317423Email:avangardpackaging-resto@yahoo.frLinkMan:Mr. ZHANG JIANG 电话:above 传真: above 邮箱:above 网址:above 采购本类产品及:above |
|||